Choose BYT1-45Z/6 when

Sep 08, 2026

Competitive Comparison

Model Thrust Stroke Ex protection Standard / mount Best fit
BYT1-45Z/6  450 N 60 mm Ex d I Mb + IIB T4 Legacy JB/ZQ (YT1 bolt pattern) Mine / gas Zone, drop-in legacy
BEd30/5 (防爆 Ed) 300 N 50 mm Ex (modern Ed) Modern DIN / JB/T 10603 New Ex equipment, lower thrust
YT1-25ZC/4 250 N 40 mm None (IP54) Legacy JB/ZQ 4388 Non-hazardous, cushioned return
Ed30/5 300 N 50 mm None (IP65) Modern DIN 15430 Non-hazardous general duty

✓ Choose BYT1-45Z/6 when

Hazardous area (methane, coal dust, IIB gas) - Ex certification is mandatory.

Existing YT1 / JB/ZQ 4388 bracket - direct swap, no rework.

Supply is 380 / 660 / 1140 V mine-standard.

Pairing with BYWZ / BJZ / BYZ explosion-proof drum brakes.

✗ Do NOT choose when

Area is non-hazardous - Ed30/5 or YT1-25ZC/4 is cheaper & lighter.

You need long stroke / high thrust - step up to BYT1-90Z/8, 180Z/12 or 320Z/20.

You need a standalone actuator (this is a brake accessory, not a cylinder-with-rod - see DYTZ700 for that).

Working Principle & Safety Logic

① ENERGISE

Motor spins centrifugal pump → oil pressure in cylinder rises

→

② EXTEND

Piston + push rod rise rapidly → lever compresses brake spring → BRAKE RELEASES

→

③ DE-ENERGISE

Pump stops, pressure drops → return spring + gravity retract rod → BRAKE LOCKS

Structural fail-safe: the spring wants the brake locked 100% of the time. Hydraulic pressure is the only thing that overcomes it. Power loss, cable break, short circuit and pump failure all converge on the same safe state - locked. This is why the thruster must never be welded, pinned or bypassed in the extended position.

Installation & maintenance rules

Mount vertically; allowable tilt ≤ 10° from vertical.

Fill oil before first run (units typically ship dry); use the specified hydraulic oil for the ambient range.

Check oil level via sight plug periodically; change per duty-cycle schedule (heavy S1/S3 mine service = shorter interval).

Do not weld, tie or block the push rod - destroys fail-safe behaviour.

Verify Ex cable gland tightness and flameproof joint gap at every inspection (methane ingress invalidates certification).