BYT1-320Z/12 Explosion Protected And Electro Hydraulic Thruster

BYT1 flameproof electro-hydraulic pusher (hereinafter referred to as pusher) is suitable for driving and controlling devices such as clamping devices, valves, gates, dummies, etc. It is mainly used as the brake release of electro-hydraulic drum brakes, and can also be used for various movements through various forms of lever-mounted Q/JZHF01-2009 flameproof electro-hydraulic pusher technology. This product is the standard part of the executive enterprise. The explosion-proof sign is "Exdl is suitable for coal mine belt conveyor (EXDL is suitable for coal mine belt conveyor).

Description

BYT1 flameproof electro-hydraulic pusher (hereinafter referred to as pusher) is suitable for driving and controlling devices such as clamping devices, valves, gates, dummies, etc. It is mainly used as the brake release of electro-hydraulic drum brakes, and can also be used for various movements through various forms of lever-mounted Q/JZHF01-2009 flameproof electro-hydraulic pusher technology. This product is the standard part of the executive enterprise. The explosion-proof sign is "Exdl is suitable for coal mine belt conveyor (EXDL is suitable for coal mine belt conveyor).

 

installation adjustment and use requirements
Installation of propeller
6.1.1 First, check whether the model on the nameplate of the propeller is consistent with the requirements.
6.1.2 When the propeller leaves the factory, there is no working oil, so it cannot be used directly. When it is used, first add pure hydraulic oil from the oil filling hole (5) to the oil level hole (3), and pay attention to pulling the push rod up and down several times during the oil filling process, so as to eliminate air and make the oil fill the oil cylinder, and then tighten the screw plug.
6.1.3 Propeller is used for vertical installation or inclined installation, which shall not exceed the soil.
15 degrees, the connecting rod (7) faces upward 0.
6.1.4 When the installed pusher moves, it should ensure that the pusher can swing as a whole, and the push rod is not allowed to bear the radial force of 0.
6.1.5 Propeller shall be equipped with qualified motor with flame-proof certificate.
6.1.6 When wiring the propeller motor, carefully compare the wiring of the motor nameplate.
6.1.7 The diameter of the lead-in cable of the motor should be consistent with the hole of the rubber pad, so as to ensure that the rubber pad is close to the cable and the outlet, otherwise, the flameproof F will be lost.
can